Escalator common faults and elimination methods

1. Escalator steps failure
The steps are the standing places for passengers to take the escalator and are also a continuously operating component. Due to environmental conditions, human factors, the machine itself and other reasons. The main faults include: the escalator combs are broken; the main shaft hole of the bracket is broken; the bracket cover is broken; the main wheel is degummed. Troubleshoot the step fault: replace the steps; replace the bracket; replace the bracket cover; replace the main wheel; replace the entire step, Sanjin has stock of OTIS, KONE, Schindler, Thyssenkrupp, Mitsubishi, Hyundai, BLT, Sigma steps and combs for replacement.
2. Traction chain failure
The traction chain is the largest force-bearing component of the escalator. Due to long-term operation, the wear is correspondingly serious. The main faults include: failure of the lubrication system; severe wear of the traction chain; and severe elongation of the traction chain. Traction chain troubleshooting method: replace the traction chain; adjust the tensioning device of the traction chain; remove the dust of the traction chain.
3. Failure of the drive unit
The main faults include: abnormal sound of the drive unit; the temperature rise of the drive unit is too fast.



2018年12月20日星期四

OTIS elevator upgrade underway at IOWA county offices

A US$1.2-million modernization by Otis is underway at the Scott County Administrative Center in Davenport, Iowa, the Quad-City Times reports. It involves two elevators at the center, which houses offices, and two at the courthouse. Offices that are inaccessible have been relocated until the work is complete in late January or early February 2019. Courthouse elevator work is expected to be complete by June 2019. The maintenance coordinator for the county’s Facility & Support Department said the project includes the units’ inner workings, and added, “Our service calls have gone up in past years, but the bigger motivating factor was being in compliance with 2020 [elevator] code changes.”


Elevator Modernization-Shaanxi Sanjin Elevator Fittings Co.,LTD.

2018年12月18日星期二

Escalator handrail joint machine

Recently, Shaanxi Sanjin Elevator researched a equipement for escalator handrail joint, which consisted of mould heating mould,  distribution box. Available for escalator handrail, Otis, Schindler,Kone,etc. For customer, it is convenient to joint according to the needed length. Save lots of time and energy.

Believe it is a good news for customer and escalator using handrail.