Basic Requirements for Elevator Maintenance

1. Elevator maintenance is required once a week for no less than two hours. Maintenance personnel are required to maintain the elevator at regular intervals.
2. Check all parts below elevator to ensure it works normally, cleanly and lubricates.
2.1. Power switch and safety switch.
2.1.1 The main switch and limit switch of the control cabinet are complete and undamaged, and the wiring is firm.
2.1.2. Check the contact of fuse and fuse. The contacts are firm and there should be no fire.
2.1.3. Safety switches, such as emergency stop, safety window, bottom hole and limit, should be in good contact and operate normally and reliably. No spanning.
2.2. Drawing machine: Appearance body should be clean and bright.
2.2.1 Reducer
A. The operation should be smooth without abnormal vibration.
B. The oil level height of the gearbox shall be kept within the prescribed oil level line.

C. The oil temperature of the reducer shall not exceed 85 C.
2.2.2. Motor
A. There should be no friction, collision or other noise in the operation of the motor. If there is any abnormal noise, the ladder should be stopped to check whether there is foreign body intruding into the sliding bearing and whether the bearing is damaged.
B. The oil level of the motor should be near the center of the oil mirror.
C. The ambient temperature of the motor should not be higher than 40 C, and the temperature rise should not be higher than the nameplate stipulation.
D. The displacement of motor bearings is less than 4 mm.
2.3. Brake.
2.3.1. Stable and reliable operation, no slippage, no less than 70% of the contact surface of the brake shoe.

The Function of Elevator Frequency Converter


The Function of Elevator Frequency Converter:
Elevator frequency converter is divided into door system frequency converter and main control system frequency converter.
The door system frequency converter also called door controller,it is used to control the lateral running speed of the door panel.
The main control system frequency converter also called main drive or inverter,it is used to control the longitudinal running speed of the car.
The common point is that the elevator speed and power saving are achieved by adjusting the frequency of the radio wave.
Shaanxi Sanjin Elevator Fittings Co., Ltd. can provide you with a variety of safety gears of different specifications for your choice,such as KONE  KDM,V3F16L,KDL16L,KDL16R,KDL16S inverters, schindler VF33BR main drive,Panasonic door controller ,selcom ,fermater ,anliso door controller and so on. Welcome to send inquiries and place orders.